Solar Engineering and Design

Develop coordinated electrical, civil and installation documentation based on verified site information and equipment limits.

Check the complete operating envelope

Select the inverter using array DC capacity, AC connection limits and the expected generation profile. Verify maximum DC voltage, MPPT voltage range, input current and short-circuit current against the chosen modules and string arrangement, including temperature effects.

Design the electrical system together

Cable sizing, voltage drop, isolation, earthing, surge protection and string protection belong in the same electrical design. Equipment with similar power ratings is not automatically interchangeable. Follow the manufacturer limits and the requirements of the relevant grid operator.

Commission and document

Record protection settings, test results, communication configuration and as-built drawings. Investigate alarms using the specific device model and operating conditions. Backup operation requires a compatible architecture and separation from the grid; a standard grid-connected system is not an emergency power supply.

Discuss your project

Share the location, system capacity and service requirements so that we can define a suitable scope.

Request a Quote